International Trade Fair for Die Casting: Technology, Processes, Products

18 - 20 January 2022 // Nuremberg, Germany

Posting print layout

What information should be shown in the print layout?

Create print layout
Exhibitors & Products EUROGUSS 2022
Zoom Image LOGO_X-Ray Fluorescence

X-Ray Fluorescence

LOGO_X-Ray Fluorescence

X-Ray Fluorescence

Request information Request information

Contact us

Please enter your personal information and desired appointment. You can also leave us a message.

Your personal information

Your message for us

Desired appointment during the exhibition

* Compulsory fields you must fill in.

Information on data protection can be found here.

Send
Your message has been sent.

You do not have a registration yet? Register now and use all advantages of the Exhibitors and Products Database, the supporting programme and the TicketShop.

An error has occurred.

X-Ray Fluorescence (XRF) spectrometry is a non-destructive analytical tecnique based on the characteristic emission of X-Ray photons by atoms when returning to the ground state after an excitation. This property is used to obtain elemental information from different types of materials in several fieds.

The basic Energy-Dispersive XRF (ED-XRF) set-up consists of an X-Ray tube as the excitation source, a sample housing and a semi-conductor detector which allows to discriminate between different energy photons. The angles between the incident X-Ray beam, the sample and detector are equal to 45 degrees in order to minimize the scattered background.

TXRF is founded on the same principles of the EDXRF with, however, one significant difference. In contrast to EDXRF, where the primary beam strikes the sample at an angle of 45 degrees, TXRF uses a glancing angle of a few milliradians with the detector positioned very close to the sample at 90 degrees.

Owing to this grazing incidence, the primary beam is totally reflected by a flat substrate (carrier) onto which the sample is deposited in liquid/slurry form and then dried in order to leave only a thin residue film, ideally some nanometer thick. The total reflection condition provides an enhanced fluorescence excitation, while the reduced thickness allows to get rid of any matrix effect: thus, the signal to background ratio is enhanced and for each element a simple linear relationship between its characteristic fluorescence peak intensity and concentration exists.

Quantitative analysis can be performed by adding an internal standard to the sample solution/suspension, i.e. an element which is not present in the original sample (usually Ga, Sc, Co or Y). Then a small droplet, about 5-100 μL, is taken from the solution/suspension with the internal standard and deposited onto the carrier.

The technique is generally non-destructive and it is suitable for solids, liquids, powders and alloys. Depending on the sample, analysis can be carried out on the "as is" specimen or after a treatment step, e.g. dilution, digestion, ashing, on-site enrichment etc. In many cases, the correct sample preparation is instrumental in getting low LOD and accurate qualification.

top

The selected entry has been placed in your favourites!

If you register you can save your favourites permanently and access all entries even when underway – via laptop or tablet.

You can register an account here to save your settings in the Exhibitors and Products Database and as well as in the Supporting Programme.The registration is not for the TicketShop and ExhibitorShop.

Register now

Your advantages at a glance:

  • Advantage Save your favourites permanently. Use the instant access – mobile too, anytime and anywhere – incl. memo function.
  • Advantage The optional newsletter gives you regular up-to-date information about new exhibitors and products – matched to your interests.
  • Advantage Call up your favourites mobile too! Simply log in and access them at anytime.